Severity: Notice
Message: Trying to access array offset on value of type null
Filename: mysqli/mysqli_driver.php
Line Number: 120
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time
Filename: Session/Session.php
Line Number: 282
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: session_set_cookie_params(): Cannot change session cookie parameters when headers already sent
Filename: Session/Session.php
Line Number: 294
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time
Filename: Session/Session.php
Line Number: 304
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time
Filename: Session/Session.php
Line Number: 314
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time
Filename: Session/Session.php
Line Number: 315
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time
Filename: Session/Session.php
Line Number: 316
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time
Filename: Session/Session.php
Line Number: 317
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time
Filename: Session/Session.php
Line Number: 375
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: session_set_save_handler(): Cannot change save handler when headers already sent
Filename: Session/Session.php
Line Number: 110
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: session_start(): Cannot start session when headers already sent
Filename: Session/Session.php
Line Number: 143
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Vital Sign Monitor KPM-A100 is a four parameter compact spot check device with graphic trends to illustrate patient status. Smooth crevice-free exterior with integrated handle aids portable usage reducing cross infection. Advanced software enables instant data download and tele-monitoring.
Vital Parameters |
|
||||||
Display | 240 x 320 dot matrix colour TFT | ||||||
NIBP Measurement range | Adult: 30-255 mmHg Paediatric: 30-160 mmHg | ||||||
NIBP Mode | Auto, Manual, STAT | ||||||
NIBP Parameters | SYS, DIA, MAP | ||||||
NIBP interval | Auto mode: 1, 2 , 3, 5, 10, 15, 20, 25, 30, 45, 60 mins STAT mode: 5 mins | ||||||
Resolution | 1 mmHg | ||||||
NIBP Over-pressure protection | Adult: 300 mmHg Pediatric: 22 mmHg | ||||||
SpO2 Measurement range | 0 - 100% | ||||||
SpO2 Accuracy | ±2% (90-100)%, ±3% (70-89)%, <70% (unspecified) | ||||||
SpO2 Resolution | 0.01 | ||||||
PR Measurement range | 30 bpm - 250 bpm | ||||||
PR Accuracy | ±1 bpm | ||||||
PR Resolution | 1bpm | ||||||
Temp Probe | Body sensitive temperature sensor | ||||||
Temp Measurement range | 0⁰C to 50⁰C | ||||||
Temp Accuracy | ± 0.1⁰C | ||||||
Temp Resolution | 0.1⁰C | ||||||
Graphic LCD size | 44 x 59 mm | ||||||
Audio-visual Alarms | Sensor-off alarm, Measurement out of user-defined limits | ||||||
Data Transmission | USB-based transmission to PC Internet-based tele monitoring | ||||||
Operational Temperature | 0⁰C to 45⁰C | ||||||
Relative Humidity | 15% to 95% | ||||||
Pressure | 86 kPa – 106 kPa | ||||||
Power Supply | Input power: AC 100-240V, 50-60Hz, 0.7A Output power: 5V,2.5A | ||||||
Battery | 2.8 A built-in rechargeable Li-ion battery Run Time : 5 hours Charging Time : 8 hours |
Used in OPD, diagnostic centers, emergency wards, first-aid and rescue ambulatory care intended for spot checking, non-invasive monitoring or recording of vital body parameters.