A PHP Error was encountered

Severity: Notice

Message: Trying to access array offset on value of type null

Filename: mysqli/mysqli_driver.php

Line Number: 120

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time

Filename: Session/Session.php

Line Number: 282

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_set_cookie_params(): Cannot change session cookie parameters when headers already sent

Filename: Session/Session.php

Line Number: 294

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time

Filename: Session/Session.php

Line Number: 304

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time

Filename: Session/Session.php

Line Number: 314

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time

Filename: Session/Session.php

Line Number: 315

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time

Filename: Session/Session.php

Line Number: 316

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time

Filename: Session/Session.php

Line Number: 317

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time

Filename: Session/Session.php

Line Number: 375

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_set_save_handler(): Cannot change save handler when headers already sent

Filename: Session/Session.php

Line Number: 110

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Cannot start session when headers already sent

Filename: Session/Session.php

Line Number: 143

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

Vital Sign Monitor KPM-A200
Vital Sign Monitor KPM-A200
Vital Sign Monitor KPM-A200

KPM-A200 is a battery operated vital sign monitor suitable for adult pediatric and neonate. Equipped with 4 hour capacity removable and rechargeable battery. Custom configuration includes SpO2, NIBP, ECG, TEMP and built-in printer option.

Get Quote
Specification
Vital Parameters 3 Parameters (SpO2 (with PR), NIBP, & 1-channel TEMP)
NIBP Measurement range Systolic Adult 50 ~ 265 mmHg Child 25 ~ 135 mmHg Diastolic Adult 15 ~ 220 mmHg Child 12 ~ 110 mmHg MAP Adult 25 ~ 245 mmHg Child 18 ~ 120 mmHg
NIBP Mode Manual, Auto
NIBP Parameters Sys, Dia, MAP
NIBP interval Auto Mode: 1 ~ 240 min, < 10 s
NIBP Over-pressure protection Adult: 300 mmHg Child: 140 mmHg
SpO2 Measurement range 35 % ~ 100 %
SpO2 Accuracy 75 % ~ 100 % @ ± 2 % 35 % ~ 74 % @ ± 3 %
PR Measurement range 30 bpm ~ 250 bpm
PR Accuracy ±2 bpm
TEMP Monitoring range 21 ⁰C ~ 50 ⁰C
TEMP Monitoring accuracy ±0.1 ⁰C
TEMP Responding time ≤ 150 s
Recording speed 25 mm/s
Recording speed accuracy ≤ 5%
Power Supply AC 100-250V, 50-60Hz
Battery 12 V, 2.3 AH (Lead-acid battery)
Features

  •  Trend review up to 400 groups of NIBP data
  •  Large storage capacity
  •  Audio-visual alarm system
  •  Nurse call system
  •  Network connectivity(Optional)

Applications

Used in OPD, diagnostic centers, emergency wards, first-aid and rescue ambulatory care intended for spot checking, non-invasive monitoring or recording of vital body parameters.

Download Catalog

Download Catalog Vital Sign Monitor KPM-A200

Patient Monitoring System | Vital Sign Monitor KPM-A200
  • Phone Number

  • +1 587 885 1415

line
  • Email Address

  • info@labnix.com