A PHP Error was encountered

Severity: Notice

Message: Trying to access array offset on value of type null

Filename: mysqli/mysqli_driver.php

Line Number: 120

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time

Filename: Session/Session.php

Line Number: 282

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_set_cookie_params(): Cannot change session cookie parameters when headers already sent

Filename: Session/Session.php

Line Number: 294

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time

Filename: Session/Session.php

Line Number: 304

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time

Filename: Session/Session.php

Line Number: 314

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time

Filename: Session/Session.php

Line Number: 315

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time

Filename: Session/Session.php

Line Number: 316

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time

Filename: Session/Session.php

Line Number: 317

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time

Filename: Session/Session.php

Line Number: 375

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_set_save_handler(): Cannot change save handler when headers already sent

Filename: Session/Session.php

Line Number: 110

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Cannot start session when headers already sent

Filename: Session/Session.php

Line Number: 143

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

Stationary X-Ray Machine KSX-A201
Stationary X-Ray Machine KSX-A201
Stationary X-Ray Machine KSX-A201

Stationary X-Ray Machine KSX-A201 is a fixed type traditional X-ray imaging modality equipped with single focus X-ray source and full wave rectification high-voltage generator for reliable performance. The high voltage X-ray generator has an independent configuration for electrical isolation subsequently increasing safety and stability. X-ray tube incorporates space charge compensator and pressure regulator to ensure the sharp images and low X-ray dosage on every output.

Get Quote
Specification
Exposure Voltage 50 kV ~ 125 kV
Exposure Current Small focus: (50, 100) mA
Big focus: (50, 100, 200 and 300) mA
Max. Output Voltage 120 kV
Max. Output Current 300 mA (instant)
Exposure Time 0.04 s ~ 6.3 s, 23 grades
Supply Voltage Adjustable
380 V: 340 V—420 V
220 V: 195 V—250 V
Supply Frequency 50 Hz
Glide Up/Down > 400 mm
HV Generator 120 kVA
X-Ray Focus Big: 2x2 mm
Small: 1x1 mm
Features

  •  Standard Frequency X-Ray Generator
  •  High Quality Imaging
  •  Accurate Timer Controlled Exposure
  •  Suitable for Radiography as well as Fluoroscopy
  •  Step-less Adjustability of Controls

Applications

Used in hospital radiology departments, orthopedic and diagnostic imaging centers to perform projection radiography.

Medical Diagnostic | Stationary X-Ray Machine KSX-A201
  • Phone Number

  • +1 587 885 1415

line
  • Email Address

  • info@labnix.com