A PHP Error was encountered

Severity: Notice

Message: Trying to access array offset on value of type null

Filename: mysqli/mysqli_driver.php

Line Number: 120

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time

Filename: Session/Session.php

Line Number: 282

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_set_cookie_params(): Cannot change session cookie parameters when headers already sent

Filename: Session/Session.php

Line Number: 294

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time

Filename: Session/Session.php

Line Number: 304

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time

Filename: Session/Session.php

Line Number: 314

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time

Filename: Session/Session.php

Line Number: 315

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time

Filename: Session/Session.php

Line Number: 316

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time

Filename: Session/Session.php

Line Number: 317

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time

Filename: Session/Session.php

Line Number: 375

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_set_save_handler(): Cannot change save handler when headers already sent

Filename: Session/Session.php

Line Number: 110

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: session_start(): Cannot start session when headers already sent

Filename: Session/Session.php

Line Number: 143

Backtrace:

File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once

Fetal Doppler KFD-A100
Fetal Doppler KFD-A100
Fetal Doppler KFD-A100

Fetal Doppler KFD-A100 is a hand held ultrasound doppler with heart-rate display and audio output. Doppler probe ensures increased sensitivity with easy-grip design. LCD display indicates fetal heart rate, volume and battery status. Built-in loudspeaker enables clear audibility of fetal heart sounds.

Get Quote
Specification
Ultrasound frequency 2 MHz
Ultrasound Intensity <10mW/cm2
Screen Alphanumeric LCD
Display Digital FHR
FHR Measuring range 50 ~ 240 bpm
Battery
Option AOption B
1.5 V AA battery Ni-MH rechargeable battery
Power consumption <1 W
FHR resolution 1 bpm
FHR accuracy ± 1 bpm
Dimension 135 × 95 × 35 mm
Weight 500 g
Features

  •  High sensitivity doppler probe
  •  Low power consumption
  •  Compact battery powered operation
  •  Provision for earphones
  •  Alpha-numeric backlit LCD

Applications

Used in gynacology clinics and obstetric department in hospitals to detect and monitor fetal heart rate for routine checkup.

Download Catalog

Download Catalog Fetal Doppler KFD-A100

Ultrasonic Doppler | Fetal Doppler KFD-A100
  • Phone Number

  • +1 587 885 1415

line
  • Email Address

  • info@labnix.com