Severity: Notice
Message: Trying to access array offset on value of type null
Filename: mysqli/mysqli_driver.php
Line Number: 120
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time
Filename: Session/Session.php
Line Number: 282
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: session_set_cookie_params(): Cannot change session cookie parameters when headers already sent
Filename: Session/Session.php
Line Number: 294
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time
Filename: Session/Session.php
Line Number: 304
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time
Filename: Session/Session.php
Line Number: 314
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time
Filename: Session/Session.php
Line Number: 315
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time
Filename: Session/Session.php
Line Number: 316
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time
Filename: Session/Session.php
Line Number: 317
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time
Filename: Session/Session.php
Line Number: 375
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: session_set_save_handler(): Cannot change save handler when headers already sent
Filename: Session/Session.php
Line Number: 110
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: session_start(): Cannot start session when headers already sent
Filename: Session/Session.php
Line Number: 143
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Anaesthesia System KAM-A101 is equipped with color LCD screen for clear display of trends, dosage rate and other setting parameters. Designed to suit adult as well as pediatric patients. System complies with closed, semi-closed, semi-open or assisted ventilation. Integrated sensors and valves ensure risk prevention from system failure and increases patient safety.
Drive | Electronically controlled, bellow driven |
Tidal Volume | 0 ml – 1500 ml |
Gas Configuration | O2, N2O |
Flow Meter | 1 l/min – 10 l/min |
LCD Display | 7 inch LCD |
Vaporizer | Single [Isoflurane / Enflurane / Sevoflurane / Halothane] |
Fresh Gas Compensation | 25 l/min – 75 l/min |
I:E Range | 4:1-1:8 |
Monitoring | VT, MV, BPM, Paw |
Modes of Ventilation | IPPV, SIMV, SIPPV, Manual |
Respiration range | 1 bpm – 100 bpm |
Concentration Range | 0% to 5% |
Calibration | Automatic |
Waveforms | Pressure-time, Flow-time, Pressure-volume loop |
Hypoxic Safety System | N2O cut-off valve / O2 > 25% |
Alarm | AC power failure, minute volume too high (low), airway pressure too high ( low ) and insufficiency of O2 and N2O |
Pressure Safety Valve | < 12.5 kPa |
Volume of CO2 absorber | 1.5 L |
Power Consumption | 50 VA |
Power Supply | 100 VAC – 240 VAC, 50 / 60 Hz |
Battery | [Rechargeable Lead-acid battery] 30 minutes ~ 120 minutes |
Working Condition | Patient airway pressure range: - 2 kPa ~ 10 kPa Airway monitoring range: 0 ~ 9.9 kPa Pressure limit range: 2.0 kPa ~ 6.0 kPa |
Dimensions | 1190 x 410 x 710 mm |
Weight | 82 Kgs |
Used in Surgical or Gynaecological departments to administer appropriate anaesthesia dosage at a specified rate to ensure effective sedation during surgeries and other invasive diagnostic or interventional procedures.
+1 587 885 1415
info@labnix.com