Severity: Notice
Message: Trying to access array offset on value of type null
Filename: mysqli/mysqli_driver.php
Line Number: 120
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time
Filename: Session/Session.php
Line Number: 282
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: session_set_cookie_params(): Cannot change session cookie parameters when headers already sent
Filename: Session/Session.php
Line Number: 294
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time
Filename: Session/Session.php
Line Number: 304
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time
Filename: Session/Session.php
Line Number: 314
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time
Filename: Session/Session.php
Line Number: 315
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time
Filename: Session/Session.php
Line Number: 316
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time
Filename: Session/Session.php
Line Number: 317
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: ini_set(): Headers already sent. You cannot change the session module's ini settings at this time
Filename: Session/Session.php
Line Number: 375
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: session_set_save_handler(): Cannot change save handler when headers already sent
Filename: Session/Session.php
Line Number: 110
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Severity: Warning
Message: session_start(): Cannot start session when headers already sent
Filename: Session/Session.php
Line Number: 143
Backtrace:
File: /home1/srokosmy/public_html/labnix/index.php
Line: 315
Function: require_once
Syringe pump KSP–B100
Syringe pump KSP–B100 is a dual-channel light–weight, infusion device designed for low volume infusion. Equipped with separate LCD screen to display independent flow parameters. Inbuilt software system accurately delivers infusion rate and monitors infusion therapy. Memory log system stores last setting of infusion parameters for fast infusion. |
Channel | Dual channel infusion |
Volume (VTBI) | 0.1 ml – 1999.9 ml |
Injection Compliance | Adaptable for 10 syringe sizes |
Accuracy | ≤ ± 3 % |
KVO Rate | 0.1 ml/h – 5 ml/h (steps : 0.1 ml/h) |
Occlusion System | 3 selectable occlusion levels |
Infusion Rate | 0.1 ml/h ~ 1600 ml/h, increment 0.1ml/h |
Syringe Size | Channel 01 : 5 ml / 10 ml / 20ml / 30ml / 50ml Channel 02 : 6 ml / 12 ml / 25 ml / 35 ml / 60 ml |
Bolus | Syringe 50 ml: 1600 ml/h Syringe 30 ml: 900 ml/h Syringe 20 ml: 600 ml/h Syringe 10 ml: 400 ml/h Syringe 5 ml: 200 ml/h |
Occlusion Alarm Threshold | High: 110 kPa ± 20 kPa (825 mmHg ± 150 mmHg) Medium: 80 kPa ± 30 kPa (600 mmHg ± 225 mmHg) Low: 60 kPa ± 20 kPa (450 mmHg ± 150 mmHg) |
Display | 4.3” color segment LCD screen |
Environmental conditions : Operation | Ambient Temperature: 5 °C to 40 °C Relative Humidity: 20 % to 90 % Atmospheric Pressure: 86 kPa to 106 kPa |
Environmental conditions : Storage | Ambient Temperature: –30 °C to 55 °C Relative Humidity: ≤ 95% Atmospheric Pressure: 50 kPa – 106 kPa |
Alarm | Occlusion, nearly finish, finish, standby (no operation), low battery, battery exhausted |
Power Supply | 100 V ~ 240 V, 50 Hz / 60 Hz |
Power Consumption | ≤ 25 VA |
Safety | Class I Type CF |
Dimensions | 354 × 132 × 199 mm |
Weight | 2.8 kg |
Features :
|
Applications :Used in general ward, ICU in hospital to gradually administer intra-venous fluid drug dosage at a predetermined rate through syringe for consistent and effective infusion therapy. |
Labnix CB03-4516 VALIANT DR NW, Calgary, AB T3K 0Y1, Canada Email: info@labnix.com | Website: https://labnix.com/ | Phone: +1 587 885 1415 |
+1 587 885 1415
info@labnix.com